Large Steam Sterilizer

  • MEDICAL
  • Large Steam Sterilizer
  • HS-5035

HS-5035

  • The Front
  • The Rear (double door)
  • The Front (open, double door)
  • The Front (open, single door)

  • The Front
  • The Rear (double door)
  • The Front (open, double door)
  • The Front (open, single door)

Highlights
Scroll down

  • 01 Substantial Chamber Capacity

    This sterilizer, which has a practical medium sized chamber between large and small sized sterilizer and is very effective to load the volumed loads, uses the saturated vapor as sterilant supplied from the built-in steam generator or external steam supply system. The chamber with jacket is the most sound structurally and the door is sealed firmly by a locking system with radial levers.

  • 02 Variable Cycle Programs and Self-Diagnosis Program

    This sterilizer has 5 kinds of optimized basic cycle program for sterilizing general medical instruments and 2 kinds of test program are embedded in the controls of sterilizer. Therefore operator can select a proper cycle conveniently for sterilizing a load and change the parameters of program easily according to the sterilizing condition. The self-diagnosis program generates the warning signal, displays the error code on the control panel and aborts the executing cycle for safety automatically in case that any operating error has occurred during cycle executing.

  • 03 Safety

    The door would not be opened without power supplying and cycle does not start unless the door is locked. The door locking system is designed to seal the chamber simply by the radial lever type. To open the door safely under chamber pressure, turn the door handle counter clockwise, then the radial levers are released and the vapor is leaked through the gap between chamber edge and door. Strong opening/closing mechanism and heat-blocking door plate cover would protect the operator from a possible accident during sterilizing. In case the chamber pressure exceeds in the set value, the safety valve exhausts the vapor from the chamber and then decreases the chamber pressure.

  • 04 Built-in Printer

    The built-in panel printer prints out the cycle performance record for securing the traceability afterwards.

Specifications

Model HS-5035
Style

Single Door

Double Door

Overall Dimension W1,010 x D1,349 x H1,715 ㎜ W1,010 x D1,460 x H1,715 ㎜
Chamber W500 x D1,000 x H700 ㎜, Vol: 350ℓ, Material: STS 316L
Loading System Loading Car: W460 x D950 x H600 ㎜ Carriage: W450 x D1,270 x H800 ㎜
Loading Shelf: W446 x D926 x H26 ㎜, Q'ty: 4 EA
Operating Temperature 121.0℃ ~ 135.0℃
Air Removal Vacuum / Gravity
Controls Microprocessor
Display Graphic LCD (LED back-light)
Printer Direct Thermal Printing, Printing paper roll: W58 x Ø40 mm
Power Source Built-in Steam Generator: AC 220V, 3ph, 50/60㎐, 55A or
AC 380V, 3ph, 4wire, 50/60㎐, 32A
Use External Steam: AC 220V, 50/60㎐, 5A
Steam Source Built-in Steam Generator: Heater 20㎾, Water Pump
External Steam Supply System: Saturated Steam of 97% Dryness
Pressure; 3.50~5.00bar Flow Rate; max. 50 ㎏/hr
Water Source Pressure: 2.10 ~ 5.00 bar, Flow Rate: Max. 50 ℓ / min
Vacuum System Water Ejector, Water Pump
Option Water Saving Device / Cooling Device
Total Weight Unit: 770㎏
Loading Car: 36㎏
Carriage: 27 ㎏
Unit: 890 ㎏
Loading Car: 36 ㎏
Carriage: 27㎏ x 2
Environment Conditions ㆍ Altitudes up to 2,000 meters
ㆍ Temperature range of + 5℃ to + 40℃
ㆍ Maximum relative humidity of 80%
ㆍ Main supply voltage fluctuation of ±10% of nominal
ㆍ Installation Category (Overvoltage Category) Ⅱ, Pollution Degree 2