硫멸퇏湲
怨좎븬利앷린硫멸퇏湲
7 liters/  21 liters/
22 liters/  35 liters/  41 liters/
60 liters/  85 liters/  200 liters/
250 liters/  350 liters/  700 liters/
1000 liters/  1500 liters/  2000 liters/
118 liters(for Field Hospital) 
E.O. 媛뒪硫멸퇏湲
41 liters/  85 liters/  135 liters/
250 liters/ 350 liters/  700 liters/
E.O. Gas Monitoring System/
Process Monitoring System/
삩 뵆씪利덈쭏 硫멸퇏湲
41 liters/  63 liters/  135 liters
諛곗뼇湲걔룰굔뿴硫멸퇏湲
32 liters/  53 liters/  108 liters/
쓽猷뚯슜 깋옣怨&깋룞怨
옄쇅꽑냼룆湲
옱떒젒李⑷린
꽍怨좎젅떒湲
Fetus Pulse Detector
BI 씤걧踰좎씠꽣
Home Sterilizer Steam Sterilizer
멸균기 │ 고압증기멸균기 시리즈
22 liters
 HS-2522BL   HS-2522SD   HS-2522N 
1 2
*Click image to enlarge the image.
HS-2522N 
(N-Class, Digital LED Display Monitor type)

This N-Class small steam sterilizer equipped with the cylindrical chamber is proper to sterilize economically the non-wrapped medical devices and instruments used frequently in the health care facilities.


1. Economic sterilization by gravity displacement
This is an economic steam sterilizer that removes air in the chamber by the gravity displacement for sterilizing the unwrapped medical devices and instruments, and is equipped with the new type external steam generator which can vaporize water instantly and inject the saturated vapor into the chamber as a sterilizing media. Thus the required cycle time is shortened and the chamber is less contaminated than the internal steam generating type, moreover the usable space in the chamber was widened due to the chamber without heater.


2. Use of clean steam every cycle
The used water(condensate) after completing a sterilizing cycle is collected in the collection container designed separately with the reservoir and should be drained to the outside manually through the built-in drain valve when the collection container is full, therefore the saturated vapor generated by a clean water always can be supplied to perform every sterilizing cycle.


3. Various cycle programs of the optimum condition
5 kinds of the basic cycle program composed of the optimum sterilization parameters are installed in this sterilizer and the operator can select a proper cycle program among them conveniently for sterilizing, moreover user can change the set values of the basic cycle programs at user's pleasure if necessary for applying to a special sterilization condition or materials.


4. Safe and convenient self-diagnosis function
By the self-diagnosis function of control program, an error occurring during operating this sterilizer is detected in real time and its code is displayed on the LED panel digitally accompanying an audible alarm, and the cycle in progress is aborted automatically for securing the safety in the workplace. 5. Convenient monitoring of cycle progressing
The operator is able to check the cycle progressing conveniently on the control panel and the pressure gauge indicates the actual chamber pressure in real time.


6. Cycle Execution Data Storing and Ubiquitous Function
The cycle performance records executed at least for 11 years are stored in the control unit in order. The user can automatically search the results of sterilization cycle performed previously by input the date performed cycle or the cycle count number and prints out the result record by the built-in panel printer. (optional specification)
The user can download or backup those data in the USB memory and monitor the operation of sterilizer on the external PC by connecting the USB or LAN cable to the built-in communication ports. Moreover the communication program including an ubiquitous function provided allows user to manage the operation of plural(maximum 15 sets) sterilizers at once. (optional specification)


7. Safe and durable unwelded chamber
By adopting an integral chamber unwelded, the durability is excellent and a trouble such as leaking of pressurized vapor during progressing a cycle is not occurred accidently.


8. Printing of the cycle performance record
The panel printer can be equipped to print out the cycle performance record for securing the traceability afterwards.
(The panel printer is provided as an optional item)
Model HS-2522N
Overall Dimension W513 x D625 x H442 ㎜
Chamber IDØ255×L447 mm, Vol: 22ℓ, Material: STS 316LL
Max. Working Pressure: 2.40bar, Max. Working Temperature: 138.0℃,
Test Pressure : 5.13bar
Tray W195 x D375 x H18 ㎜, Q'ty: 2ea
Reservoir/Collection Container Vol: 6.0ℓ / 6.0ℓ (full water level)
Operating Temperature 121.0℃~135.0℃ (Display Resolution: 0.1℃ )
Sterilant Saturated Steam
Air Removal Method Gravity Displacement
Controls Microprocessor
Display Digital LED Display
Panel Printer (optional) Direct Thermal Printing type
Printing Paper Roll: W58xØ40 mm L=13 m
Power Source AC 220V, 50/60Hz
Power Consumption 2,200 W
Weight 47 kg
ENVIRONMENT
CONDITIONS
(IEC61010-1)
ㆍ Altitudes up to 2,000 meters.
ㆍ Temperature range of +5℃ to +40℃.
ㆍ Maximum relative humidity of 80% temperature up to 31℃ decreasing linearlyto 50% relative humidity at 40
ㆍ Main supply voltage fluctuation of ±10% of nominal.
ㆍ Installation Category (Overvoltage Category) Ⅱ, Pollution Degree 2.