硫멸퇏湲
怨좎븬利앷린硫멸퇏湲
7 liters/  21 liters/
22 liters/  35 liters/  41 liters/
60 liters/  85 liters/  200 liters/
250 liters/  350 liters/  700 liters/
1000 liters/  1500 liters/  2000 liters/
118 liters(for Field Hospital) 
E.O. 媛뒪硫멸퇏湲
41 liters/  85 liters/  135 liters/
250 liters/ 350 liters/  700 liters/
E.O. Gas Monitoring System/
Process Monitoring System/
삩 뵆씪利덈쭏 硫멸퇏湲
41 liters/  63 liters/  135 liters
諛곗뼇湲걔룰굔뿴硫멸퇏湲
32 liters/  53 liters/  108 liters/
쓽猷뚯슜 깋옣怨&깋룞怨
옄쇅꽑냼룆湲
옱떒젒李⑷린
꽍怨좎젅떒湲
Fetus Pulse Detector
BI 씤걧踰좎씠꽣
Home Sterilizer Steam Sterilizer
멸균기 │ 고압증기멸균기 시리즈
350 liters
 HS-5035   HS-5035PT (Automatic Sliding Door type) 
1 2 3 4 5
*Click image to enlarge the image.
HS-5035 

1. Substantial Chamber Capacity
This sterilizer, which has a practical medium sized chamber between large and small sized sterilizer and is very effective to load the volumed loads, uses the saturated vapor as sterilant supplied from the built-in steam generator or external steam supply system. The chamber with jacket is the most sound structurally and the door is sealed firmly by a locking system with radial levers.



2. Variable Cycle Programs and Self-Diagnosis Program
This sterilizer has 5 kinds of optimized basic cycle program for sterilizing general medical instruments and 2 kinds of test program are embedded in the controls of sterilizer. Therefore operator can select a proper cycle conveniently for sterilizing a load and change the parameters of program easily according to the sterilizing condition. The self-diagnosis program generates the warning signal, displays the error code on the control panel and aborts the executing cycle for safety automatically in case that any operating error has occurred during cycle executing.



3. Safety
The door would not be opened without power supplying and cycle does not start unless the door is locked. The door locking system is designed to seal the chamber simply by the radial lever type. To open the door safely under chamber pressure, turn the door handle counter clockwise, then the radial levers are released and the vapor is leaked through the gap between chamber edge and door. Strong opening/closing mechanism and heat-blocking door plate cover would protect the operator from a possible accident during sterilizing. In case the chamber pressure exceeds in the set value, the safety valve exhausts the vapor from the chamber and then decreases the chamber pressure.



4. Built-in Printer
The built-in panel printer prints out the cycle performance record for securing the traceability afterwards.
Model HS-5035
Style Single Door (S) Double Door (D)
Overall Dimension W1,010 x D1,349 x H1,715 ㎜ W1,010 x D1,460 x H1,715 ㎜
Chamber W500 x D1,000 x H700 ㎜,   Vol:  350ℓ,   Material:  STS 316L
Loading System Loading Car:  W460 x D950 x H600 ㎜   Carriage:  W450 x D1,270 x H800 ㎜
Loading Shelf:  W446 x D926 x H26 ㎜,   Q'ty:  4 EA
Operating Temperature 121.0℃ ~ 135.0℃
Air Removal Vacuum / Gravity
Controls Microprocessor
Display Graphic LCD (LED back-light),   Resolution;  160 x 128 dots
Printer Direct Thermal Printing,  Printing paper roll:  W58 x Ø40 mm
Power Source Built-in Steam Generator:  AC 220V, 3ph, 50/60㎐, 55A   or
                                                AC 380V, 3ph, 4wire, 50/60㎐, 32A
Use External Steam:  AC 220V, 50/60㎐, 5A
Steam Source Built-in Steam Generator:   Heater  20㎾,   Water Pump  300W
External Steam Supply System: Saturated Steam of 97% Dryness 
                                           Pressure;  3.50~5.00bar   Flow Rate;  max. 50 ㎏/hr
Water Source Pressure:  2.10 ~ 5.00 Bar,   Flow Rate:  Max. 50 ℓ / min
Vacuum System Water Ejector,   Water Pump (490W) / Optional: Waterring Vacuum Pump
Total Weight 833 ㎏ 980 ㎏
Unit 770㎏
Loading Car 36㎏
Carriage 27 ㎏
Unit 890 ㎏
Loading Car 36 ㎏
Carriage 27㎏ x 2
Environment Conditions * Altitudes up to 2,000 meters.
* Temperature range of + 5℃ to + 40℃.
 * Maximum relative humidity of 80%.
* Main supply voltage fluctuation of ±10% of nominal.
* Installation Category (Overvoltage Category) Ⅱ,   Pollution Degree 2.